Concealed Shower Rough-In Valve Checklist: Depth, Pressure Test & Serviceability
Pre-wall engineering checklist for concealed brass shower mixer valves: wall cavity depth, thread standard lock, pre-tile pressure testing, and cartridge access.
Every concealed in-wall shower system succeeds or fails before the first tile is laid. Contractors must lock four checkpoints prior to wall closure: (1) confirm solid brass rough-in body depth matches finished tile thickness, (2) verify native 1/2" NPT or G1/2" BSP inlets without adapters, (3) run a full pre-tile pressurized leak test, and (4) confirm front-access cartridge/diverter serviceability without breaking tiles.